Standard Series
Full Flush Steel Stiffened Door
The Securall® standard steel stiffened Full Flush Steel Door is a symbol of excellence in quality, construction and functionality. The design allows for a smooth finish that gives a strong look and feel to the door. The flush door is an ideal match for Commercial and Residential use in almost any application.
The door panel is constructed by placing both halves of the door panel together using our interlocking channel system. The internal core of the door is constructed with steel stiffeners that extend the entire height of the door panel and are adhered to both sides of the door panel. |
|
Knock Down or Welded Steel Frames
The Securall® standard Knock Down or Welded Steel Frames are excellent for both residential and commercial use. The knock down and welded options allow our doors to be versatile depending on the application.
The knock down option is a great choice for existing construction where a pre-existing opening is already prepared for a door. The three separate pieces of the frame make it easy to install one piece at a time to ensure an exact fit and secure holding ability for the specific wall construction.
The pre-welded option works very well for new construction. The doors can be placed in their openings and the wall can be easily built around the frame, making the structure more firm as a whole.
Securall® offers a unique option of Factory Pre-installation of hardware to make it easier for you, the end user. This option is designed to help streamline the process of receiving and installing doors. By choosing to have Securall® professionally install all of the hardware at our factory, the contractor saves hours of onsite labor and the costs associated with it.
Insulation: Foam board insulation is used to thermally insulate the door. The foam board has an R value of 9.
Standard Models - 80" H |
|
Standard Models - 84" H |
Door Width (in.) |
Panels |
Model No. |
Weight (lbs.) |
|
30 |
Single |
HD30x80 |
151 |
36 |
Single |
HD36x80 |
169 |
42 |
Single |
HD42x80 |
205 |
60 |
Double |
HD60x80 |
253 |
72 |
Double |
HD72x80 |
265 |
|
|
|
Door Width (in.) |
Panels |
Model No. |
Weight (lbs.) |
|
30 |
Single |
HD30x84 |
157 |
36 |
Single |
HD36x84 |
175 |
42 |
Single |
HD42x84 |
205 |
60 |
Double |
HD60x84 |
265 |
72 |
Double |
HD72x84 |
277 |
|
|
|
SECURALL® Standard Steel Doors Feature:
- 18-gauge primed galvannealed Steel door panels.
- 16-gauge primed galvannealed steel frame.
- Door thickness 1 ¾ inches.
- Reinforced core
- Reinforced at hardware locations.
|
Fire Rating
Maximum Hourly Fire Rating |
Available Gauges |
Maximum Door Size |
Door |
45 Minute Fire Rated
|
18
|
48"Wx96"H |
Single Door |
84"Wx96"H |
Double Door |
1-1/2 Hour Fire Rated
|
18
|
48"Wx96"H |
Single Door |
84"Wx96"H |
Double Door |
3 Hour Fire Rated
|
18
|
42"Wx84"H |
Single Door |
84"Wx84"H |
Double Door |
|
|
Also availalble in 16 gauge up to 3 hour at a 72" width maximum.
Doors Specifications
| NFPA 80 - Fire Doors and Fire Windows. |
| ASTM A568 - Standard Specification for Steel Sheet, Carbon and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements for. |
| ASTM A591/A591M - Standard Specification for zinc coatings produced by electro-deposition for light coating weight [mass] applications on steel sheet. |
| ASTM A653 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process. |
| ASTM A924 - Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process. |
| ASTM A1008 - Standard Specification for Steel Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability. |
| ASTM A1011 - Standard Specification for Steel Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability. |
| ANSI/SDI A250.3 - Test Procedure and Acceptance Criteria for Factory Applied Finish Painted Steel Surfaces for Steel Doors and Frames. |
| ANSI/SDI A250.4 - Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames, Frame Anchors and Hardware Reinforcings. |
| ANSI/SDI A250.6 - Recommended Practice for Hardware Reinforcing on Standard Steel Doors and Frames. |
| ANSI/SDI A250.8 - SDI-100 Recommended Specifications for Standard Steel Doors and Frames; 1998. |
| ANSI/SDI A250.10 - Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and Frames. |
| ANSI/SDI A250.11 - Recommended Erection Instructions for Steel Frames (Formerly SDI-105). |
| DHI A115.1G - Installation Guide for Doors and Hardware. |
| SDI 111 - Recommended Standard Details for Steel Doors & Frames. |
| ANSI/NFPA 252 - Fire Tests of Door Assemblies. |
| ANSI/UL 10B - Fire Tests of Door Assemblies. |
| ANSI/UL 10C - Positive Pressure Fire Tests of Door Assemblies. |
| ANSI/UL 1784 - Air Leakage Tests of Door Assemblies |
| UL - Building Materials Directory; Underwriters Laboratories Inc. |
| WH - Certification Listings; Warnock Hersey International Inc. |
Special & Custom Steel Doors